C0500 error code

I am also facing this trouble, with Di3510. some time machine work for many copies fine. then suddenly the 0500 error code appear. I checked complete fuser unit... Both lamps are ok, Thermo switch is ok, i checked both thermistors and in my view they are ok (checked with multimeter while warming them). I first reset the code as mentioned in the service manual of this machine. the code can remove but it comes back after some time. I checked the Electricity voltage as this machine is 120v input. Voltage are ok. Then i ask my Electronic board expert to check the Power supply and he told me that the power supply is ok... just some dry sold he found. So until now i am not able to detect the trouble even though i arranged another fuser unit of the same machine and it also gave the same error code c0500. As i am a Technision of copiers. Please give any good suggestion if any one have. Thanks

1 Answer

Everett Lin

Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

President:

An expert whose answer got voted for 500 times.

  • Konica Minolta Master 990 Answers
  • Posted on Jan 11, 2014
Everett Lin
Konica Minolta Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

President:

An expert whose answer got voted for 500 times.

Joined: Dec 05, 2008
Answers
990
Questions
3
Helped
441524
Points
3070

Hi, Sir;
I believed this machine come with two heater lamp, change this two lamp position, and also thermistor have to be contact heat roller perfect, try it see what happen. good luck

3 Related Answers

ikram661

  • 1 Answer
  • Posted on Jul 02, 2008

SOURCE: Code C0500

simulation = UTILIY -----> METER COUNT (on touch screen)->
STOP------> 0-----> 0------> STOP------>0------>1

Ad

Anonymous

  • 15 Answers
  • Posted on Apr 09, 2009

SOURCE: How do I get to Tech Rep Service Mode on Minoltas to clear C0500 error code?

I need to know m/c model

Anonymous

  • 1 Answer
  • Posted on Oct 10, 2009

SOURCE: machine trouble call service c0500

Try to power it up with the STOP button pressed.
If not call service team.

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

190 views

Ask a Question

Usually answered in minutes!

Top Konica Minolta Office Equipment & Supplies Experts

Norman Weimar
Norman Weimar

Level 3 Expert

7080 Answers

George Mclaughlin

Level 2 Expert

373 Answers

Cindy Wells

Level 3 Expert

6751 Answers

Are you a Konica Minolta Office Equipment and Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...