Questions & Answers for: Pentair stack Computers & Internet

Question about MASTER TEMP HEATER 400 000 BTU NG LOW NOX HD EXCHANGER

1 Answer

Pool Heater Problem Getting error E05 just after start up. What's going on? bad stack flue sensor

Ad

...E05. What next? I have same problem. Mechanic not sure what to do. May need a new board. EO5 is a stack flue error. exhaust temp is too high. problem can be from several things. bad stack flue ...

Ad

...exhaust pipe is blowing out really hot air and has singed the side of house. Tech came and saw flue stack sensor light was on and replaced flue stack sensor on advice of factory tech he spoke to by ...

Question about Mastertemp Pool & Spa Heater Dual Electronic Ignition 400,000 Btu Lonox Propane 460737

5 Answers

master temp 400 with E05 error message, already replaced stack flue sensor, thermistor, and igniter. Any suggestions? Already replaced stack flue sensor, thermistor, and igniter on my 4 year old ...

Question about Mastertemp Pool & Spa Heater Dual Electronic Ignition 400,000 Btu Lonox Propane 460737

0 Answer

Pentair MasterTemp 400 Stack Flu Sensor Reading Stuck My Pentair MasterTemp 400 has been running fine for one year. I now see symptoms as follows: 1. When heater is turned on, unit displays 888, then ...

Question about Mastertemp 460733 250k Btu Propane Pool Heater

3 Answers

error code eo5 stack flue sensor It's not always the stack flue sensor. But if the heater fires and runs for a few seconds before shutting down then it is the stack flue sensor. You can find the part ...

Question about Mastertemp 460733 250k Btu Propane Pool Heater

2 Answers

what is pentair code ad0 ado is a code for stack flue temp set up if you look at a pentair chart you can find the procedure to change that If you can’t stack sensor and it still show ado code

Question about 460732 MasterTemp Heater 250BTU ()

2 Answers

how to bypass stack flue sensor? I am getting error E05 - Is there a way to bypass stack flue sensor until new one arrives? if the flue sensor got hot and went out heater is running too hot is your ...

Question about MASTER TEMP HEATER 400 000 BTU NG LOW NOX HD EXCHANGER

2 Answers

how do i replace the stack flu sensor? Remove the side panels, now youre able to remove the wing nuts securing the top, now you can see all of the wires and components. Depending on the age of your ...

Question about MASTER TEMP HEATER 400 000 BTU NG LOW NOX HD EXCHANGER

1 Answer

...I had same issue yesterday in the field. The sensor was bad in my case. After replacement of the Stack flu sensor my stack temp was only reading 80 degrees, a clear indication that the board