Question about Tankless Hot Water Heater Rtg-74pvp-2 7.4 Gpm
and you should see 100F. With any luck you are good to go. The 82 error code means that the unit does not know what gas type is supplying the unit. The remedy is to program the PCB for proper gas type
Question about RTG-74PVN-2 Natural Gas Pronto Whole House, Natural Gas, Tankless Wat
...code 82 C2 means and how I can reset the unit? 82 is a problem iwht the high altitude chip or that the circuit board data has failed you should call a rheem service rep to come fix it. rheems number ...
Question about RTG-74PVN-2 Natural Gas Pronto Whole House, Natural Gas, Tankless Wat
...code of 82. Not certain what to do, and it's now after hours at the call center. Advice anyone? 82 means that your programming on the board isn't correct, check for the right altitude chip and fuel ...
Question about Tankless Hot Water Heater Rtg-74pvp-2 7.4 Gpm
i just replaced the pcb board on heater and is flashing code 82 how do i resolve this error code code 82 is gas type data failure. You need to program the PCB for proper gas type What is the PCB board
Question about Paloma PTG-74PVN / RTG-74PVN Natural Gas Indoor
...code -0 and 82 PTG-74PVN I am getting error code -0 and 82 flashing between the two. Unable to determine what is the cause or the fix to it. The blower turns on but then turns off after a few seconds ...
Question about Tankless Hot Water Heater Rtg-74pvp-2 7.4 Gpm
...82 code. I've put the dip switch of 1 and 2 on, and pressed the adjustor button, but get the LH code. What should I do next? is there any type of surge portection for tankless water heaters mother ...
Question about RTG53DVP Direct Vent Liquid Propane Tankless Water Heater for 12 B
code 82 Before calling service technician, open following link for resources including error codes, Rheem chat and possible manual: http://waterheatertimer.org/Troubleshoot-Rheem-Tankless-water-heater
Question about Paloma PTG-42PVN / RTG2-42PVN Natural Gas Indoor
code C2 82 on PTG-42PVN / RTG2-42PVN Natural gas indoor ERROR CODE C2 82 This error code will occur for two reasons:1. The heater has lost its programming and you will need a new programming chip from
...code that is coming up is C8 82 Before calling service tech, copy following link for Rheem-Paloma troubleshoot resources:http://waterheatertimer.org/Troubleshoot-Rheem-Tankless-water-heater.htmlC8 is ...
Question about Paloma PTG-74PVN / RTG-74PVN Natural Gas Indoor
...code 82: Error Code 82 Explanation: Gas Type Control Data Failure; Printed Circuit Board data failure. The PCB has not been programmed, lost its programming or has failed. 5. If the unit does not ...