C43 = fuser thermistor problem...

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

Toshiba copier

for e207 model, error code should be in C44, F14, and etc...
Assume your error is C43, check the fuser thermistor, clear the error using 08-400 = Any value => "0"
0helpful
1answer

E studio 520 code c447

All error code soloution of fuser unit Fuser Unit Error Status Counter
Purpose
When a fuser unit related error (error code C41, C43, C44 or C45) occurs, the set value of the fuser status
counter varies, depending on type of error.
Displaying and checking the set value of the fuser status counter can analyze a cause for the error. If
any of "2 to 9" is set at the fuser status counter, the fuser unit will not be operated for safety reasons.
After the fuser unit related error is resolved, if "0" is set, the fuser unit will be operated as usual. If any of
"10 to 19" is set at the fuser status counter, the fuser unit will be operated as usual, even if "0" is not set
after the fuser unit related error is resolved.
C41: Thermistor or heater abnormality at power-ON
C43: Thermistor abnormality after abnormality judgment
C44: Heater abnormality after abnormality judgment
C45: Thermistor abnormality during printing
C46 to C49: Reserved
Description
When this code is used, the current set value of the fuser status counter is displayed. Only "0" can be
manually entered, in order to restore the fuser unit to its normal operation, after the fuser unit related
error is resolved.
For further reason why the counter value differs despite the same error code, refer to 5.1.7 or 5.1.8
[Fuser unit related service call] in the Service Handbook.
0: No error 10: C47 (Reserved)
1: C41 (Once) 11: C47 (Reserved)
2: C41 (Consecutively occurs) 12: C48 (Reserved)
3: C46 (Reserved) 13: C49 (Reserved)
4: C43 14: C47 (Reserved)
5: C44 15: C48 (Reserved)
6: C45 16: C49 (Reserved)
7: C44 17: C47 (Reserved)
8: C45 18: C48 (Reserved)
9: C44 19: C49 (Reserved)
* Default: 0
Setting Timing
Use this code to resolve the fuser unit related error (error code C41, C43, C44 or C45). Resolve the
error, and set "0" (or reset the counter), in order to restore the fuser unit to its normal operation.
Caution
Remember to resolve the fuser unit related error, and then reset to "0." also 447
0helpful
1answer

Error code c43

All error code soloution of fuser unit Fuser Unit Error Status Counter
Purpose
When a fuser unit related error (error code C41, C43, C44 or C45) occurs, the set value of the fuser status
counter varies, depending on type of error.
Displaying and checking the set value of the fuser status counter can analyze a cause for the error. If
any of "2 to 9" is set at the fuser status counter, the fuser unit will not be operated for safety reasons.
After the fuser unit related error is resolved, if "0" is set, the fuser unit will be operated as usual. If any of
"10 to 19" is set at the fuser status counter, the fuser unit will be operated as usual, even if "0" is not set
after the fuser unit related error is resolved.
C41: Thermistor or heater abnormality at power-ON
C43: Thermistor abnormality after abnormality judgment
C44: Heater abnormality after abnormality judgment
C45: Thermistor abnormality during printing
C46 to C49: Reserved
Description
When this code is used, the current set value of the fuser status counter is displayed. Only "0" can be
manually entered, in order to restore the fuser unit to its normal operation, after the fuser unit related
error is resolved.
For further reason why the counter value differs despite the same error code, refer to 5.1.7 or 5.1.8
[Fuser unit related service call] in the Service Handbook.
0: No error 10: C47 (Reserved)
1: C41 (Once) 11: C47 (Reserved)
2: C41 (Consecutively occurs) 12: C48 (Reserved)
3: C46 (Reserved) 13: C49 (Reserved)
4: C43 14: C47 (Reserved)
5: C44 15: C48 (Reserved)
6: C45 16: C49 (Reserved)
7: C44 17: C47 (Reserved)
8: C45 18: C48 (Reserved)
9: C44 19: C49 (Reserved)
* Default: 0
Setting Timing
Use this code to resolve the fuser unit related error (error code C41, C43, C44 or C45). Resolve the
error, and set "0" (or reset the counter), in order to restore the fuser unit to its normal operation.
Caution
Remember to resolve the fuser unit related error, and then reset to "0."
2helpful
1answer

Call for service C 430

All error code soloution of fuser unit Fuser Unit Error Status Counter
Purpose
When a fuser unit related error (error code C41, C43, C44 or C45) occurs, the set value of the fuser status
counter varies, depending on type of error.
Displaying and checking the set value of the fuser status counter can analyze a cause for the error. If
any of "2 to 9" is set at the fuser status counter, the fuser unit will not be operated for safety reasons.
After the fuser unit related error is resolved, if "0" is set, the fuser unit will be operated as usual. If any of
"10 to 19" is set at the fuser status counter, the fuser unit will be operated as usual, even if "0" is not set
after the fuser unit related error is resolved.
C41: Thermistor or heater abnormality at power-ON
C43: Thermistor abnormality after abnormality judgment
C44: Heater abnormality after abnormality judgment
C45: Thermistor abnormality during printing
C46 to C49: Reserved
Description
When this code is used, the current set value of the fuser status counter is displayed. Only "0" can be
manually entered, in order to restore the fuser unit to its normal operation, after the fuser unit related
error is resolved.
For further reason why the counter value differs despite the same error code, refer to 5.1.7 or 5.1.8
[Fuser unit related service call] in the Service Handbook.
0: No error 10: C47 (Reserved)
1: C41 (Once) 11: C47 (Reserved)
2: C41 (Consecutively occurs) 12: C48 (Reserved)
3: C46 (Reserved) 13: C49 (Reserved)
4: C43 14: C47 (Reserved)
5: C44 15: C48 (Reserved)
6: C45 16: C49 (Reserved)
7: C44 17: C47 (Reserved)
8: C45 18: C48 (Reserved)
9: C44 19: C49 (Reserved)
* Default: 0
Setting Timing
Use this code to resolve the fuser unit related error (error code C41, C43, C44 or C45). Resolve the
error, and set "0" (or reset the counter), in order to restore the fuser unit to its normal operation.
Caution
Remember to resolve the fuser unit related error, and then reset to "0."
1helpful
1answer

Error c44 studio

codes c43, c44, c45
problem with the fuser
thermistor review
thermal fuse
check connectors
3helpful
1answer

TOSHIBA E STUDIO 207 ERROR C 44

All error code soloution of fuser unit Fuser Unit Error Status Counter
Purpose
When a fuser unit related error (error code C41, C43, C44 or C45) occurs, the set value of the fuser status
counter varies, depending on type of error.
Displaying and checking the set value of the fuser status counter can analyze a cause for the error. If
any of "2 to 9" is set at the fuser status counter, the fuser unit will not be operated for safety reasons.
After the fuser unit related error is resolved, if "0" is set, the fuser unit will be operated as usual. If any of
"10 to 19" is set at the fuser status counter, the fuser unit will be operated as usual, even if "0" is not set
after the fuser unit related error is resolved.
C41: Thermistor or heater abnormality at power-ON
C43: Thermistor abnormality after abnormality judgment
C44: Heater abnormality after abnormality judgment
C45: Thermistor abnormality during printing
C46 to C49: Reserved
Description
When this code is used, the current set value of the fuser status counter is displayed. Only "0" can be
manually entered, in order to restore the fuser unit to its normal operation, after the fuser unit related
error is resolved.
For further reason why the counter value differs despite the same error code, refer to 5.1.7 or 5.1.8
[Fuser unit related service call] in the Service Handbook.
0: No error 10: C47 (Reserved)
1: C41 (Once) 11: C47 (Reserved)
2: C41 (Consecutively occurs) 12: C48 (Reserved)
3: C46 (Reserved) 13: C49 (Reserved)
4: C43 14: C47 (Reserved)
5: C44 15: C48 (Reserved)
6: C45 16: C49 (Reserved)
7: C44 17: C47 (Reserved)
8: C45 18: C48 (Reserved)
9: C44 19: C49 (Reserved)
* Default: 0
Setting Timing
Use this code to resolve the fuser unit related error (error code C41, C43, C44 or C45). Resolve the
error, and set "0" (or reset the counter), in order to restore the fuser unit to its normal operation.
Caution
Remember to resolve the fuser unit related error, and then reset to "0."
1helpful
1answer
0helpful
2answers

Error code C43

Please specify he machine brand and model
Not finding what you are looking for?

365 views

Ask a Question

Usually answered in minutes!

Top Toshiba Office Equipment & Supplies Experts

Norman Weimar
Norman Weimar

Level 3 Expert

7080 Answers

Sudeep Chatterjee
Sudeep Chatterjee

Level 3 Expert

3269 Answers

Grand Canyon Tech
Grand Canyon Tech

Level 3 Expert

3869 Answers

Are you a Toshiba Office Equipment and Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...